Product details
| Part number | 4007-9201 |
|---|---|
| Description | 100 Point Eps FACP, Red |
| Category | Fire Alarm Control Panels / 4007ES Panels |
| System | Simplex 4007ES fire alarm panels |
| Works with | IDNet communicating devices and TrueAlarm sensors (IDNet 2 SLC), TrueAlert ES and TrueAlert addressable notification appliances (IDNAC SLC), … |
| Approvals | UL 864 (UOJZ, UOXX, SYZV); UL 2017 (FSZI); ULC-S559; ULC-S527; CSFM (Listing 7165-0026:0378); FM approved; NYC Fire Dept COA #6191A |
| Availability | In stock in Riyadh |
| Support | Selection, compatibility and programming help from our engineers |
Need it for a project?
Tell us the quantity and the panel or system it is for. We confirm compatibility, price and delivery, and can install and program it.
About the 4007-9201
The 4007-9201 is the red-cabinet 4007ES fire alarm control unit with addressable initiation and addressable notification. It has an IDNet 2 SLC for 100 addressable points, expandable to 250 with up to two 4007-9803 loop expansion modules, and a 3 A Class B IDNAC SLC for up to 127 TrueAlert or TrueAlert ES addressable notification appliances. It runs stand-alone or on an ES Net or 4120 network (with a NIC) and is operated from a 4.3 in. color touchscreen.
Batteries larger than 18 Ah do not fit in the cabinet and need the 4009-9801 external battery cabinet.
Specifications
| Addressable points | 100 on the IDNet 2 SLC; up to 250 with two 4007-9803 IDNet 2 Loop Expansion Modules |
|---|---|
| IDNAC SLC | 3 A, Class B, regulated 29 VDC during Alarm, 127 addresses, 139 unit loads |
| Power supply output | 4 A output for "Special Application" appliances |
| Input power | 120 VAC input 2 A maximum @ 102 VAC to 132 VAC, 50/60 Hz; 240 VAC input 1 A maximum @ 204 VAC to 264 VAC, 50/60 Hz |
| Panel current | 180 mA supervisory, 185 mA alarm |
| Battery charging | 6.2 Ah up to 33 Ah (batteries larger than 18 Ah require a remote battery cabinet) |
| Cabinet | Red, surface or semi-flush mounting; rated NEMA 1 and IP30 |
| Operating environment | 32°F to 120°F (0°C to 49°C); up to 93% RH, non-condensing @ 90°F (32°C) maximum |
Used with
- 4007-9803 – IDNet 2 Loop Expansion Module, adds 75 points, maximum of two
- 4007-9801 – Eight Point Zone/Relay Module (one included as standard, up to three more)
- 4007-9806 – SDACT Module for Point or Event Reporting
- 4009-9801 – External battery cabinet for batteries up to 33 Ah
- 2975-9812 – Red semi-flush box trim
From Simplex datasheet S4007-0002. The datasheet and UL listing can be downloaded under Documents above.