Skip to Content
Part no. 4098-9613

SSD Heat Detector - 135 Ror

94.88 SAR 94.88 SAR

  • Brand
  • weight
  • Manufacturer
  • Detectable Method
  • Detection
  • Genuine manufacturer parts
  • Stock and delivery from Riyadh
  • Technical support from our engineers: +966 11 216 0987

Product details

Part number4098-9613
DescriptionSSD Heat Detector - 135 Ror
CategoryDetectors & Bases / Smoke, Heat & Multi Sensors
System Simplex TrueAlarm detectors and TrueAlert appliances
Works withConventional 2-wire IDCs (2-wire bases), 4-wire IDCs (4098-9682 base, separate 24 VDC), 4090-9101 and 4090-9106 Zone Adapter Modules (IDNet or MAPNET II), …
ApprovalsUL listed to UL 521; ULC; CSFM; FM approved
AvailabilityIn stock in Riyadh
SupportSelection, compatibility and programming help from our engineers

Need it for a project?

Tell us the quantity and the panel or system it is for. We confirm compatibility, price and delivery, and can install and program it.

About the 4098-9613

Conventional thermistor-based heat detector with fixed temperature operation at 135° F (57° C), plus rate-of-rise detection, for Simplex 2-wire and 4-wire bases. It is self-restoring, has an alarm LED on the detector, and gives a current limited alarm that works on 2-wire initiating device circuits (IDCs). It is for normal ambient temperatures of 32° to 100° F (0° to 38° C); heat detectors are for property protection, and Simplex recommends smoke detection where life safety is a factor.

On a 2-wire IDC that uses Alarm Verification for smoke detectors, mount this detector on the 4098-9682 4-wire base.

Specifications

Fixed temperature135° F (57° C)
Rate-of-rise operationBetween 15° & 25° F/min (8.33° & 13.88° C/min)
UL & ULC maximum spacing70 ft x 70 ft (21.3 m x 21.3 m)
FM maximum spacing / RTI20 ft x 20 ft (6.1 m x 6.1 m); Quick
Voltage15 to 32 VDC (filtered DC with 30% maximum ripple)
Standby current80 µA typical, 100 µA maximum
Alarm current2-wire: up to 86 mA maximum, set by the IDC current limit; 4-wire: 24 mA typical @ 24 VDC
Ambient operating range32° to 100° F (0° to 38° C)

Used with

  • 4098-9788 – 2-Wire Base, no options
  • 4098-9684 – 2-Wire Base with connection for remote LED alarm indicator
  • 4098-9683 – 2-Wire Base with auxiliary alarm relay output
  • 4098-9682 – 4-Wire Base with auxiliary alarm relay output
  • 4098-9832 – Adapter plate for 4 in. square or octagonal box

From Simplex datasheet S4098-0014. The datasheet can be downloaded under Documents above.

Specifications

Brand Simplex
weight 0.20 lbs
Manufacturer Johnson Control
Detectable Method RoR & Fixed
Detection Heat