Skip to Content
Part no. 4007-9101

100 Point FACP, Red

5,517.70 SAR 5,517.70 SAR

  • Genuine manufacturer parts
  • Stock and delivery from Riyadh
  • Technical support from our engineers: +966 11 216 0987

Product details

Part number4007-9101
Description100 Point FACP, Red
CategoryFire Alarm Control Panels / 4007ES Panels
System Simplex 4007ES fire alarm panels
Works withIDNet 2 devices and TrueAlarm sensors, Simplex ES Net network, Simplex 4120 network, 4009 IDNet NAC Extender, 4606-9202 / 4606-9205 RUI touchscreen annunciators
ApprovalsUL 864 (UOJZ, UOXX, SYZV); UL 2017 (FSZI); ULC-S527; ULC-S559; CSFM Listing 7165-0026:0378; FM approved; NYC Fire Dept COA #6191A
AvailabilityIn stock in Riyadh
SupportSelection, compatibility and programming help from our engineers

Need it for a project?

Tell us the quantity and the panel or system it is for. We confirm compatibility, price and delivery, and can install and program it.

About the 4007-9101

4007ES Hybrid fire detection and control unit in a red cabinet, with addressable and conventional initiation. It has one IDNet 2 SLC for up to 100 addressable points (up to 250 with two 4007-9803 loop expansion modules), four conventional NACs, a 6 A power supply/battery charger and one 8-point zone/relay module for conventional IDCs or relays. It is operated from a 4.3 in. color touchscreen and can run stand-alone or on an ES Net or 4120 network.

The cabinet holds batteries up to 18 Ah; 25 Ah and 33 Ah batteries need the 4009-9801 external battery cabinet.

Specifications

Input power120 VAC input: 2 A maximum @ 102 VAC to 132 VAC, 50/60 Hz; 240 VAC input: 1 A maximum @ 204 VAC to 264 VAC, 50/60 Hz
Display4.3 in. (109 mm) diagonal color touchscreen
Addressable capacityOne IDNet 2 SLC, up to 100 points; up to 250 with two 4007-9803 modules
NACsFour onboard Class B/Class A NACs, 3 A each for Special Application Appliances, 2 A each for Regulated 24 DC Appliances
Power supply output6 A total
Battery charging6.2 Ah up to 33 Ah; batteries larger than 18 Ah require a remote battery cabinet
Supervisory / alarm current145 mA / 190 mA
Operating temperature32°F to 120°F (0°C to 49°C)

Used with

  • 4007-9803 – IDNet 2 Loop Expansion Module, +75 points, maximum of two
  • 4007-9801 – Eight Point Zone/Relay Module, up to three additional
  • 4009-9801 – External battery cabinet for up to 33 Ah batteries
  • 4007-9806 – SDACT Module for Point or Event Reporting
  • 4606-9202 – Color LCD touchscreen remote annunciator, red

From Simplex datasheet S4007-0001. The datasheet and UL listing can be downloaded under Documents above.