Skip to Content
Part no. 49VO-WRSO-BA

Weatherproof Add Strobe Wall Red NO Label (BA)

660.10 SAR 660.10 SAR

660.10 SAR incl. VAT
  • Genuine manufacturer parts
  • Stock and delivery from Riyadh
  • Technical support from our engineers: +966 11 216 0987

Product details

Part number49VO-WRSO-BA
DescriptionWeatherproof Add Strobe Wall Red NO Label (BA)
CategoryNotification Appliances / TrueAlert ES Addressable Appliances
System Simplex TrueAlarm detectors and TrueAlert appliances
Works with4100ES with EPS+ or EPS Power Supply (IDNAC), 4007ES with IDNAC Notification, 4010ES with ESS Enhanced System Supply (IDNAC), 4009 IDNAC Repeater
ApprovalsUL 1971 (indoor, 15 or 75 cd); UL 1638 (outdoor, WP75 or WP185); CSFM; FM approved
AvailabilityOn request, ask for lead time
SupportSelection, compatibility and programming help from our engineers

Need it for a project?

Tell us the quantity and the panel or system it is for. We confirm compatibility, price and delivery, and can install and program it.

About the 49VO-WRSO-BA

UL listed weatherproof TrueAlert ES addressable strobe (visible only) for wall mounting indoors or outdoors, with a red cover with no lettering and a clear lens. It is powered, supervised and controlled from an IDNAC signaling line circuit; intensity is set from the panel or by jumper to 15 or 75 cd indoors (UL 1971) or WP75 or WP185 outdoors (UL 1638), with a synchronized 1 Hz flash. It must be mounted on a matching weatherproof box, ordered separately; models ending in -BA are assembled in the USA.

The weatherproof mounting box 49WPBB-AVVOWR (red) or 49WPBB-AVVOWW (white) is required and is ordered separately.

Specifications

Strobe intensity15 or 75 cd (UL 1971, indoor); WP75 or WP185 (UL 1638, outdoor)
Operating voltage23 VDC to 31 VDC, Special Application
Current at 23 VDC60 mA (15 cd), 160 mA (75 cd), 160 mA (WP75), 185 mA (WP185); 212 mA (WP75) and 239 mA (WP185) below 32°F
Temperature range32° to 120° F (0° to 49° C) at 15 or 75 cd; -31°F to 150°F (-35° C to 66°C) at WP75 or WP185
Humidity range10% to 93%, at 100° F (38° C) (UL 1971); up to 98%, at 104 °F (40° C) (UL 1638)
Supervisory requirements1 unit load (= 0.8 mA control panel current)
EnclosureNEMA 3R
WiringTerminal blocks for 18 AWG to 12 AWG (0.82 mm² to 3.31 mm²)

Used with

  • 49WPBB-AVVOWR – Red surface mount weatherproof mounting box (required)
  • 49VOC-WRS-O – Separate red V/O weatherproof cover, blank
  • 4905-9929 – TrueAlert addressable wiring isolator

From Simplex datasheet S49WP-0001. The datasheet can be downloaded under Documents above.