Skip to Content
Part no. 4090-9006

Sup Release Periph & Enclosure

1,338.60 SAR 1,338.60 SAR

  • Genuine manufacturer parts
  • Stock and delivery from Riyadh
  • Technical support from our engineers: +966 11 216 0987

Product details

Part number4090-9006
DescriptionSup Release Periph & Enclosure
CategoryAddressable Modules & Interfaces / Addressable Modules (IAM/ZAM/Isolators)
System Simplex fire alarm systems
Works with4100ES (with Suppression Releasing Appliqué), 4100U (software revision 11.05 or higher), IDNet, 4009 IDNet NAC Extender
ApprovalsUL, ULC, CSFM listed; FM approved; MEA (NYC) acceptance; CSFM Listing 7300-0026:313 (SRP); this boxed model is the one required for ULC listing
AvailabilityIn stock in Riyadh
SupportSelection, compatibility and programming help from our engineers

Need it for a project?

Tell us the quantity and the panel or system it is for. We confirm compatibility, price and delivery, and can install and program it.

About the 4090-9006

The 4090-9006 is a Suppression Release Peripheral (SRP) supplied in a NEMA 1 red box with an LED indicator on the door. With a 4100ES (or 4100U) panel it controls and supervises the actuators of automatic extinguishing, deluge and preaction sprinkler release systems. A release needs both an IDNet command and an active NAC (dual command control), and the unit provides one releasing appliance circuit (RAC).

Each releasing circuit takes one 24 VDC actuator (or two 12 VDC actuators in series) and needs a 2081-9046 coil supervision module in the actuator wiring junction box.

Specifications

CommunicationsIDNet, one address
RAC output rating2 A maximum with 4100ES; 1 A maximum with 4009 IDNet NAC Extender (at nominal 24 VDC, regulated)
NAC input voltage16 to 32 VDC (nominal 24 VDC)
Supervisory currentNo additional current required, circuit appears as standard end-of-line (EOL) NAC loading
Wire connectionsScrew terminals for input and output wiring, 18 to 12 AWG wire (0.82 mm² to 3.31 mm²)
IDNet wiring distanceUp to 2500 ft (762 m) from the IDNet source module
Operating temperature32° F to 120° F (0° C to 49° C) indoor operation only
EnclosureNEMA 1 red box, LED indicator on front of door

Used with

  • 2081-9046 – Coil supervision module, required, one per RAC
  • 4010-9830 – Suppression Releasing Appliqué (English), required for 4100ES releasing
  • 2080-9056 – Abort switch, flush mount
  • 2080-9057 – Abort switch, surface mount
  • 2081-9044 – Overvoltage protector for IDNet wiring

From Simplex datasheet 4100-0040. The datasheet can be downloaded under Documents above.