Skip to Content
Part no. 4098-9755

Duct Sensor Housing

593.40 SAR 593.40 SAR

  • Genuine manufacturer parts
  • Stock and delivery from Riyadh
  • Technical support from our engineers: +966 11 216 0987

Product details

Part number4098-9755
DescriptionDuct Sensor Housing
CategoryDetectors & Bases / Aspirating & Duct Sampling
System Simplex TrueAlarm detectors and TrueAlert appliances
Works with4007ES, 4008, 4010, 4010ES, 4020, 4100, 4100ES, 4100E, 4120, 2120 CDT (if configured for MAPNET II, TrueAlarm operation), IDNet or MAPNET II communications
ApprovalsUL listed to UL 268A; ULC; CSFM (3240-0026.241); FM approved; MEA (NYC) MEA35-93E
AvailabilityIn stock in Riyadh
SupportSelection, compatibility and programming help from our engineers

Need it for a project?

Tell us the quantity and the panel or system it is for. We confirm compatibility, price and delivery, and can install and program it.

About the 4098-9755

The 4098-9755 is an addressable air duct smoke sensor housing with a factory-installed 4098-9714 TrueAlarm photoelectric sensor. Sampling tubes draw duct air past the sensor; the panel reads its analog value, sets the sensitivity (0.2% to 3.7% per foot) and tracks dirt build-up. This basic model has no relay output and is powered from the IDNet or MAPNET II loop.

A sampling tube sized to the duct width (4098-9854 to 4098-9858) must be ordered separately, and duct smoke detection does not replace smoke detection in open areas.

Specifications

Data communicationsIDNet or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755
Sensor sensitivity range0.2% to 3.7% per foot of obscuration, selectable at host control panel
Air velocity range300 to 4000 ft/min (91 to 1220 m/min)
UL listed temperature range32° F to 100° F (0° C to 38° C)
Operating temperature range32° F to 122° F (0° C to 50° C)
Humidity range10% to 95% RH, non-condensing
Wiring connectionsTerminal blocks, 18 to 12 AWG (0.82 mm² to 3.31 mm²)
Duct sizeRectangular or round ducts; minimum 8” (203 mm) square or 18” (457 mm) diameter

Used with

  • 4098-9854 – Sampling tube for 12” (305 mm) duct width
  • 4098-9855 – Sampling tube for 13” to 23” (330 mm to 584 mm) duct width
  • 4098-9856 – Sampling tube for 24” to 46” (610 mm to 1168 mm) duct width
  • 2098-9808 – Remote red LED status indicator, single-gang stainless steel plate
  • 2098-9806 – Remote test station with keyswitch and red LED

From Simplex datasheet 4098-0030. The datasheet and installation manual can be downloaded under Documents above.